Bioness NESS L300 Plus Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non Bioness NESS L300 Plus. The L300® Plus System Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Plus System

The L300® Plus System

Page 2 - Objectives

L300 Large Electrodes Copyright 2011 Bioness Inc.

Page 3 - Systems, Inc

Copyright 2011 Bioness Inc. L300 Plus System

Page 4 - Microstimulators

Challenges of Neurologic Gait  Usually Involves Several Joints/Muscle Groups  Complicated by Impairment in Timing, Control, and Sensation  Difficu

Page 5 - Complete Gait Systems

Challenges of Neurologic Gait  Solutions often fall short and compensatory in nature  No “one” solution works for everyone  Proximal control diffic

Page 6 -  Wellbeing

Without Stimulation With Stimulation L300 Plus System: Design Concept Example Stimulation of Hamstrings During Stance

Page 7 - FES Support and Development

Copyright 2011 Bioness Inc. L300 Plus System: Select Design Achievements  Addresses Dysfunction of Hamstrings and Quadriceps and Associated Gait/Func

Page 8 - The Large Cloth Electrode

Copyright 2011 Bioness Inc. L300 Plus System: Potential Impact on Gait  Better Knee Control  Increased Step Length  Increased Stance Time  Better

Page 9 - Simplify the Fitting Process

L300 Plus System Components Copyright 2011 Bioness Inc.  New components include the Thigh Cuff with Stimulator and multi-function Control Unit  Use

Page 10 - L300 Large Electrodes

© 2011 Bioness Inc. Confidential. 18 Thigh Functional Stimulation Cuff  Elongation bar and adjustable straps for length and girth tuning  12 “Quick

Page 11 - L300 Plus System

 Position on Thigh for Quads versus Hamstrings  Anatomical landmarks ensure accurate electrode placement  Comfortable “closed” cell materials allow

Page 12 -  Common impairments can

Objectives  Introduction to Bioness  Introduce Large Electrodes, L300 Systems  Introduce the L300 Plus System – Background – Features – Value – Pil

Page 13 - Copyright 2011 Bioness Inc

L300 Plus Control Unit Copyright 2011 Bioness Inc. Control Unit

Page 14

L300 Plus Control Unit Copyright 2011 Bioness Inc. Control Unit

Page 15 - Gait/Functional Deficits

L300 Plus Clinic Value Copyright 2011 Bioness Inc.

Page 16 -  Increased Stance Time

Intelli-Gait Plus Software Copyright 2011 Bioness Inc. Software

Page 17 - L300 Plus System Components

Intelli-Gait Plus Software Copyright 2011 Bioness Inc. Software

Page 18

© 2011 Bioness Inc. Confidential. 25 L300 Plus Videos  Provides Immediate Orthotic Benefit  Addresses issues in Swing and Stance  Therapeutic Impac

Page 19

L300 Plus Videos Copyright 2011 Bioness Inc. No Stimulation L300 Plus

Page 20 - L300 Plus Control Unit

L300 Plus Feasibility Study © 2011 Bioness Inc. Confidential. 27 Subjects:  Forty-five (45) subjects suffering from foot drop and thigh muscles weakn

Page 21

L300 Plus Feasibility Study © 2011 Bioness Inc. Confidential. 28  The study protocol duration for each subject was six weeks.  Case Series Trial

Page 22 - L300 Plus Clinic Value

L300 Plus Feasibility Study: Gait Speed © 2011 Bioness Inc. Confidential. 29 0,2 0,3 0,4 0,5 0,6 0,7 Baseline 6 Weeks M/S L300 Plus Orth

Page 23 - Intelli-Gait Plus Software

Pacesetter Systems, Inc. © 2011 Bioness Inc. Confidential.

Page 24

L300 Plus Feasibility Study: Gait Speed © 2011 Bioness Inc. Confidential. 30 0,2 0,3 0,4 0,5 0,6 Baseline 6 Weeks M/S L300 Plus

Page 25 - L300 Plus Videos

L300 Plus Feasibility Study: Symmetry © 2011 Bioness Inc. Confidential. 31 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 No Stim Baseline L300 Plus Baseline L300 Plus

Page 26

L300 Plus Feasibility Study: Outcome © 2011 Bioness Inc. Confidential. 32 Knee Hyperextension exacerbated with speed

Page 27 - L300 Plus Feasibility Study

L300 Plus Feasibility Study: Outcome © 2011 Bioness Inc. Confidential. 33 L300 Plus at Comfortable Pace: HS in Stance/Preswing

Page 28

L300 Plus Feasibility Study: Fast Pace © 2011 Bioness Inc. Confidential. 34 Fast Pace No Stimulation

Page 29 - P < .05

L300 Plus Feasibility Study: Fast Pace © 2011 Bioness Inc. Confidential. 35 L300 Plus at Fast Pace: HS in Stance/Pre-swing

Page 30 - L300 Plus Therapeutic Effect

Feasibility Study Summary  Clinical need for knee control following UMN disorder is evident  Current technology is limited, mainly compensatory, and

Page 31 - Asymmetry Index

© 2011 Bioness Inc. Confidential. 37 L300 Plus Features Review  Wireless Communication  Operates off the same Clinician’s Programmer as the L300  R

Page 32

technology 2004 - 2010 H200® EXOSKELETAL IMPLANTABLES L300 ® Microstimulators Bioness Neuromodulation Technology L300 Plus™ H200 ® Wireless Copyright

Page 33

technology Bioness Rehabilitation Technology Complete Gait Systems Copyright 2011 Bioness Inc.

Page 34 - Fast Pace No Stimulation

© 2011 Bioness Inc. Confidential. 6 Gait Dysfunction and Rehabilitation Connections with Ambulation Status:  Disability  Discharge  Falls Risk  We

Page 35

© 2011 Bioness Inc. Confidential. 7 FES Support and Development  Recommend treatment with FES for stroke patients with impaired muscle contraction.

Page 36 - Feasibility Study Summary

The Large Cloth Electrode, L300 Systems

Page 37 - L300 Plus Features Review

Simplify the Fitting Process  Large Size Cloth-Based Electrode  Simplifies fitting, greatly reduces set-up (no fitting cables)  Improves Recruitmen